H4EKO-D wood boiler

Wood boiler with manual feeding
EKO design

H4EKO‑D wood boiler with manual feeding

A+

The OPOP wood gasification boiler H4EKO‑D with manual feeding guarantees one of the lowest heating costs.

Fuel

Dry wood

Output

16 kW
20 kW
25 kW

Advantages

Minimum emissions

Emission class 5 and minimum toxic emissions.

Small boiler size

Thanks to clever design, the boiler can be placed in smaller spaces.

Cost Saving

The solid fuel boiler’s high efficiency saves heating costs.

Control unit

The electronic control unit controls the entire heating system.

The intelligent wood boiler combines classic heating with modern technology that guarantee high efficiency.

Easy Operation

  • The wood gasification boiler has a large hopper so that you don't have to refill very often.
  • It's designed for burning large pieces of wood and has low fuel consumption.
  • The boiler can be regulated by an outdoor sensor to compensate for temperature differences, ensuring a stable household temperature.
  • The boiler includes a cooling unit.
  • It's possible to add an electric coil for electric heating.

Economic operation

  • Efficiency up to 90.2%.
  • Low fuel and electricity consumption.
  • The added extraction ventilator ensures more efficient combustion and a minimum of ash.
  • It belongs to emission class 4 and meets ecodesign conditions.

Small size

  • It's also suitable for small boiler rooms with low ceilings.
  • Boilers with an output of 16 kW and 20 kW can also fit through a 60 cm width.

Boilers long service life

  • The exchanger’s 5-mm sheet thickness guarantees its long service life.
  • Warranty 5 years
Technical parameters
Types of wood boilers Unit H416 EKO-D H420 EKO-D H425 EKO-D
Nominal thermal output [kW] 16 20 25
Efficiency [%] 90 90 90,2
Required operating draught Pa 12 12 12
Weight [kg] 265 317 369
Ekodesign   yes yes yes
Boiler class according to ČSN EN 303303:-5   5 5 5
Water capacity [ l ] 33 33 54
Flue pipe diameter [mm] 130 130 130
Fuel consumption [kg/h] 4,1 5,1 6
Temperature range of heating water [°C] 65 - 85 65 - 85 65 - 85
Fuel shaft volume  [ l ] 42 62 82
Stoking hole dimensions (DxW) [cm] 35 x 22 35 x 32 35 x 42
Log length [cm] 33 33 40
Burning time at nominal output [hod] > 4 > 4 > 4
Flue gas temperature at nominal thermal output [°C] 137 130 130
Maximum heating water overpressure [MPa] 0,2 0,2 0,2
Heating water overpressure test [MPa] 0,4 0,4 0,4
Guaranteed fuel / water volume   wood, chipped / H2O max. 20%
Flue gas mass flow [kg/s] 0,01 0,0147  0,0147 
Electricity consumption / Electrical protection [W] 11 / IP 20 22 / IP 20 22 / IP 20
Supply voltage [V/A] 230/2 230/2 230/2
Dimensions
A - Boiler total height [mm] 964 964 964
B - Boiler total depth [mm] 1085 1085 1085
C - Boiler width [mm] 498 598 698
D - Fume duct position [mm] 635 635 635
E - Inlet water funnel position [mm] 109 109 109
F - Outlet water funnel position [mm] 791 791 791
H - Cooling circuit position [mm] 238 238 238
I - Heater position [mm] 173 173 173
J - Release valve position [mm] 77 77 77
Energy efficiency class  

 

Certification
Product information
Technical data
Product informations
Technical documentation