Advantages
Modern Approach
Today’s technology goes hand in hand with quality.
Small boiler size
The boilers of the Biopel MINI product line are small in size and highly efficient.
Czech tradition
Since starting boiler production in 1959, we have gained generations of experience.
Cost Saving
The solid fuel boiler’s high efficiency saves heating costs.
Small dimensions
- Compact dimensions. Very small width from 84 cm.
- Significant space saved.
Easy Operation
- Easy control of the automatic boiler control unit using a touch screen.
- With the use of accessories, the boiler can be controlled via the Internet from anywhere using a mobile phone.
- The boiler can be set to self-regulation based on the outdoor temperature.
- Quick and easy maintenance thanks to easy access to the burner and heat exchanger.
Economic and ecological operation
- High efficiency up to 93.7%.
- Low pellet consumption.
- Low emissions (emission class 5, meets ECODESIGN requirements).
Long service life
- Stainless steel burner
- Reliable electronic components
- Warranty 5 years
Boiler type | Biopel MINI 11 | Biopel MINI 15 | Biopel MINI 21 | Biopel MINI 30 | Biopel MINI 40 | |
---|---|---|---|---|---|---|
Nominal output | kW | 11 | 15 | 21 | 30 | 40 |
Minimal output | kW | 3,3 | 4,7 | 6 | 8,9 | 11,8 |
Prescribed fuel | / | Wood pellets diameter 6-8mm | ||||
Fuel consumption | kg/h | 0,77-2,36 | 1,01-3,36 | 1,38-4,68 | 1,96-6,52 | 2,64-8,42 |
Emission class | 5 / Ekodesign | |||||
Efficiency | % | 93,6 | 93,7 | 92,9 | 93,5 | 93,6 |
Water volume | L | 32 | 54 | |||
Required chimney draught | Pa | 5,5 | 7,5 | 8 | 11 | 11 |
Maximum working water pressure | Bar | 2 | ||||
Maximum heated water temperature | °C | 80 | ||||
Minimum return water temperature | °C | 55 | ||||
Flue gas temperature (with nominal thermal output) | °C | 85 | 101 | 102 | 107 | 117 |
Weight | kg | 160 | 240 | |||
Dimensions | ||||||
B Boiler height | mm | 1088 | 1257 | |||
H Boiler width | mm | 352 | 482 | |||
J Boiler depth with burner cover | mm | 1043 | 1170 | |||
K Fume duct location | mm | 281 | 308 | |||
E Display height | mm | 98 | ||||
G Total depth with automatic ash removal | mm | 1162 | 1277 | |||
F Total depth with hydraulic set | mm | 1212 | 1338 | |||
O Outlet water funnel location from the ground | mm | 822 | 992 | |||
L Fume duct position from the ground | mm | 739 | 898 | |||
N Inlet water funnel location from the ground | mm | 156 | ||||
M Release valve position from the ground | mm | 145 | ||||
P Inlet water funnel location from the fume duct | mm | 106 | 155 | |||
Q Outlet water funnel location from the fume duct | mm | 106 | 155 | |||
R Flue pipe diameter | mm | 130 | 150 | |||
X Boiler width with handrail | mm | 406 | 538 | |||
Connecting outlets | DN | G1 1/4" | ||||
A Total boiler width with container (flexible dimensions) | mm | 1600 | 1730 | |||
S Total boiler height including feeder (flexible dimensions) | mm | 1500 | ||||
A Total boiler width with container: KOMPAKT 150 | mm | 843 | 973 | |||
A Total boiler width with container: KOMPAKT 225 | mm | 1003 | 1133 | |||
X Compact container depth with feeder (150/225) | mm | 890/960 | ||||
Z1 Compact container depth with accessories type TOWER 40 | mm | 1010 | ||||
Z1 Compact container depth with accessories type TOWER 60 | mm | 1110 |
Hopper parameters (cm) | Pellet capacity (kg) | Hopper weight (kg) | A Height (mm) | B Width (mm) | C Depth (mm) |
---|---|---|---|---|---|
60x60 | 110 | 25 | 1300 | 600 | 600 |
80x80 | 220 | 29 | 1300 | 815 | 815 |
100x100 | 300 | 35 | 1300 | 1000 | 1000 |
Extended hopper | 350 | 38 | 1300 | 815 | 1420 |
Compact 225 | 225 | 45 | 1283 | 593 | 960 |
Compact 150 | 150 | 39 | 1283 | 433 | 890 |
TOWER 40 | 40 | 16 | 1386 | 352 | 720 |
TOWER 60 | 60 | 19 | 1556 | 482 | 820 |
Certification
Product information
Technical data